Solenoid Relays

Burns Part No.
BH_3007

Details

  • SPST solenoid relays - normally open contacts; one circuit: off-on
  • Y24037: Intermittent duty; 12V (pictured on left)
  • 750 amps make - 100 amps break
  • 10 sec. on - 20 min. off
  • Y24059: Continuous duty; 12V (pictured in center)
  • 85 amps continuous
  • Y24008: Intermittent duty: 24V (pictured in center)
  • 750 amps max
  • 120 amps make - 65 amps break
  • 10 sec. on - 30 min. off
  • 24063-08: Continuous duty: 24V (pictured on right)
  • 65 amps max
  • 120 amps make - 65 amps break
  • 10 sec. on - 30 min. off
  • PVC coated
  • Note: Large terminals are 5/16"-24 copper, bracket mounting is 5/16" x 9/32" holes on 2-13/16" centers.
Grouped product items
Qty Part Number Set Ascending Direction Qty In Stock Sold in Multiples Cross Reference Part Numbers Continuous or Intermittent Set Ascending Direction Grounded or Insulated Set Ascending Direction Additional Info Set Ascending Direction Replacement Numbers Set Ascending Direction Price Set Ascending Direction
24008 0 1 N/A intermittent insulated 24V, see above N/A
$27.34
24063-08 0 1 N/A continuous insulated 24V, see above N/A
$124.87
Y24037 0 1 View Case:BR534079R1

John Deere:BRAR54484
intermittent grounded 12V, see above Case IH BR534079R1, JD BRAR54484
$55.13
Y24059 3 1 View Case:BTV26961 continuous insulated 12V, see above Case IH BR1347697C1
$52.54